Ultrasonic Flowmeters

Flanged ultrasonic flowmeters provide ease of use with fixed flange mounting. As a principle of operation, it has the same characteristics as online / portable ultrasonic flow meters. The sensors are mounted on stainless steel pipe according to the preferred flange dimensions. Thanks to this, it does not require the need for sensor adjustment.

Flanged ultrasonic flowmeters are a product developed as a result of 12 years of ultrasonic flowmeter production. Thanks to the processors with high operating speed used, it has achieved a fast and reliable structure with high performance. The general characteristics of flanged stationary ultrasonic flowmeters can be listed as follows:

  • sensitivity better than 0.5%
  • Improved software that makes measurement more stable and improves performance
  • RS485 Serial communication
  • 4-20 mA and 0-10 V Analog output
  • Kanalizasyon suyu ölçebilme özelliÄŸi
  • Frequency and Pulse output feature
  • The ability to use three types of sensors: on the clamp, immersion type, pipe type
  • All settings can be stored in flash memory
  • More than 4 communication protocols can be selected: MODBUS, Meter-BUS, etc.
  • Instantaneous and total flow information can be stored in memory as month/day and can be transferred via MODBUS.
  • The fluid density can be selected
  • Pille veya 8~36VDC besleme ile çalıştırılabilir.

 

Measuring December: 0.01...30 m/s
Model: TUFF-2000SW
Accuracy: better than 0.5%
Repeatability: better than 0.2%
Measurement Principle: Transition Time Measurement Principle
Measurement Period: 500ms
Display: 2×20 Character LCD Display
Output: Pulse, Analog (4-20 mA, 0-10 V or Frequency), RS485 and Alarm Relay Output
Registration: 64 Days/64 Months and 5 Years Registration Feature with Automatic Adjustment
Connection: DN15 – DN6000
Available Pipe Material: Steel, Stainless Steel, Cast Iron, Copper, PVC, Aluminum, FRP, etc. (Provided that it is a liner)
Measurable Fluids: Water, Seawater, Industrial Wastewater, Acid/Base liquids, Alcohol, Beer and other homogeneous liquids
Temperature December: Main unit -30°C/80°C, Sensors -40°C/110°C, Immersion -40°C/150°C
Humidity December: 85%RH
Cable: Sensor Max. Connection is 20 meters, RS485 Max. Connection 1000 meters
Supply: With battery or with 8~36VDC 50mA supply
Communication Protocols: MODBUS, M-BUS, Fuji and other communication protocols

1683182447447-e1686681304792

it was founded on 03.01.2023 in Gaziantep. Engineering solutions for steam, fire, water systems.

Contact

  • Beylerbeyi, 84027 Nolu Sokak No:11/G, 27000 Åžehitkamil/Gaziantep

  • info@zenteknik.com

  • +90 342 502 58 91

  • +90 552 881 97 27

© 2024 Zen Teknik Engineering Tüm Hakları Saklıdır. | Gizlilik Politikası

Web Design Digital Küre

Message
To Contact
Zen Teknik
Hello 👋
How Can We Help You?