Volume
200 lt -1000 lt
Upper Heat Exchanger Maximum Thermal Power
161 kW
Lower Heat Exchanger Maximum Collector Area
10 m2
Lower Heat Exchanger Maximum Collector Area
110˚C
Heat exchanger Maximum Operating Pressure
10 bar
Domestic Water Maximum Operating Temperature
95˚C
Domestic Water Maximum Operating Pressure
10 bar
Interior Surface Coating
Enamel application is made in accordance with
DIN 4753-3 standard.
Manufactured according to 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS 736 and TS EN 12897 standards.
Insulation and Equipment
11.17 Solar and Heat Pump Boilers | 200L-500L | 800L-1000L | |
Isolation | STD/50 mm | x | |
x | STD/80 mm | ||
x | OPS/80 mm | ||
Izomax- 50 kg/m³ in accordance with EU Commission Regulation 814/2013 and TS EN 12897 Standard BL-S3,d0 fire reaction class insulation compliant with ErP Regulation | x | OPS/80 mm | |
Outer Case Protection | Blueshell - Heat-saving recyclable polyethylene coating | STD | x |
Vinlex - Artificial Leather | x | STD | |
x | OPS | ||
Hardware | STD/Ø63 | STD/Ø100 | |
Feeler Sleeve | STD/½” 3 adet | ||
Cleaning and Control Flange | STD/Ø100 mm | STD/Ø125 mm | |
Electric Heater | OPS/1½” | OPS/2″ | |
Cathodic Protection | Magnesium Anode | STD | STD |
Electronic Anode | OPS | OPS | |
Carrier Element | Steel leg system with three-point pallet mounting | STD | STD |
Circle steel foot system providing circular ground contact | x | x |
STD The abbreviation used for spare parts and equipment for standard products.
OPS: The abbreviation used for optional product spare parts and equipment for non-standard products.
Technical Specifications
Definition | Code | Unit | 11.17.14 | 11.17.16 | 11.17.18 | 11.17.20 | 11.17.21 | |
Volume | V | lt | 200 | 300 | 500 | 800 | 1000 | |
Insulation Type & Thickness | i | mm | PU/50 | PU/50 | PU/50 | SPU/80 | SPU/80 | |
Diameter | ØD | mm | 580 | 580 | 740 | 910 | 1010 | |
Height | H | mm | 1340 | 1860 | 1845 | 2110 | 2200 | |
Cleaning & Control Flange Diameter | N1 | inch | Ø100 | Ø100 | Ø100 | Ø125 | Ø125 | |
Electric Heater Connection | N2 | inch | 1½” | 1½” | 1½” | 2″ | 2″ | |
Thermometer / Sensing Sleeve Connections | N3 | inch/mm | ½” | ½” | ½” | ½” | ½” | ½” |
Domestic Cold Water Inlet Connection | N4 | inch | 1″ | 1″ | 1″ | 1¼” | 1¼” | |
Lower Heat Exchanger (Serpentine) Inlet/Outlet Connections | N5-N6 | inch | 1″ | 1″ | 1″ | 1″ | 1″ | |
Upper Heat Exchanger (Serpentine) Inlet/Outlet Connections | N7-N9 | inch | 1¼” | 1¼” | 1¼” | 1¼” | 1¼” | |
Circulation Return Connection | N8 | inch | 1″ | 1″ | 1″ | 1¼” | 1¼” | |
Domestic Hot Water Outlet Connection | N10 | inch | 1″ | 1″ | 1″ | 1¼” | 1¼” | |
Magnesium Anode Connection | N11 | inch | 1¼” | 1¼” | 1¼” | 1¼” | 1¼” | |
Closed Connection | N12 | inch | 1¼” | 1¼” | 1¼” | 1¼” | 1¼” | |
Lower Heat Exchanger (Serpentine) Surface Area | A | 0,73 | 0,98 | 1,35 | 1,35 | 1,35 | ||
Upper Heat Exchanger (Serpentine) Surface Area | A | 1,76 | 3,11 | 4,52 | 5,09 | 5,09 | ||
Gross Weight | G | kg | 105 | 150 | 208 | 300 | 331 | |
Overturning Dimension | R | mm | 1460 | 1950 | 1990 | 2300 | 2420 |
The above table is based on spare parts and equipment for standard products; all connections are internal threaded.
KODSAN reserves the right to change product specifications, technical dimensions and information and installation diagrams without notice.
Any information provided on this page cannot be copied and used without the permission of KODSAN. In no way can KODSAN be held responsible by citing technical information and diagrams as examples.

it was founded on 03.01.2023 in Gaziantep. Engineering solutions for steam, fire, water systems.
Quick Menu
Our Products
Contact
-
Beylerbeyi, 84027 Nolu Sokak No:11/G, 27000 Şehitkamil/Gaziantep
-
info@zenteknik.com
-
+90 342 502 58 91
-
+90 552 881 97 27
© 2024 Zen Teknik Engineering Tüm Hakları Saklıdır. | Gizlilik Politikası
Web Design Digital Küre